RINSTRUM R420-K402 DIGITAL INDICATOR
BRAND

The Rinstrum R420-K402 indicator is a comprehensive general purpose indicator designed with both the installer and operator in mind. Flexibility is the key with its award winning modular accessory design. Modules include: additional serial options, input/outputs, analogue outputs, external buttons and battery or AC option. The robust input/output has been designed for direct connection into PLC’s. Powerful product configuration allows for parameters like setpoint targets, piece weights and units conversions to be stored for each product.
Simple setup through a menu system, either directly using the alpha numeric keypad or through our Viewer programme on a PC. Operator friendly, with a large two line display using logical prompts, and dedicated and programmable function keys. Printing can be tailored with custom record, docket or reports printouts.
Applications: Weighbridges, Floor scales, Goods receiving and shipping, Parts counting, Silo weighing and Process control
Specifications
Approvals
- Australia NMI(S-418), 10,000 Divs. @ 0.7µV/Div
- EU OIML R76, 10,000 Divs. @ 0.7µV/Div
- C-Tick, CE & FCC
Physical
- Display Type LCD display;LED backlight
- Digit Size 29mm Primary,18mm Secondary
- Keypad 23 Silicon Keys
- Power Switch Front Panel with Memory
- Housing ABS Plastic IP65 front only
- Dimensions 246(W) x 121(H) x 36(D) mm
- Pack Weight 0.70 kg
- Function Keys 3 Fixed, 3 Programmable
Power
- DC 12-24 VDC
- AC 110-240 VAC (Acc)
- Battery 12V 2.5Ah NiMH (Acc)
Loadcell
- Excitation 7.4V DC
- Drive 16 x 350 ohm
- Sensitivity 100,000 div @ 0.25 µV/Div
- Linearisation 10 points
- Range Single/Dual Range, Dual Interval
Features
- Serial 1A RS232
- Serial 1B RS485 TX Only
- Accessory Slots 4
- Input/Output 32 I/O
- Set Points 8
Functions
- Counting with Piece Weight Entry,
- Clock Calendar, 4/6 Wire
- Custom Unit Switching, Hold & Peak Hold
- Custom Printing, Auto Output
- Optional extra Serial Ports
- Optional Analogue Output
Key Features
- 100,000 div @ 0.25 µV/Div
- Standard serial outputs
- Custom printing, auto output
- Counting with piece weight entry
- Programmable unit conversion
- 3 assignable function keys
- 8 set points
- 32 input/output (option)
- Analogue module with isolated outputs (option)